Nominal Size

Outer Diameter (IN)

Minimum Wall (IN)

Lifts Per Truck

Feet Per Lift

Approximate Weight
(LB/100')

Inches

Millimeters

4

100

4.800

0.267

16

1020

251.6

6

150

6.900

0.383

16

440

521.2

8

200

9.050

0.503

20

200

903.0

10

250

11.100

0.617

12

240

1364.4

12

300

13.200

0.733

28

60-80

1935.8

 

Nominal Size

Outer Diameter (IN)

Minimum Wall (IN)

Lifts Per Truck

Feet Per Lift

Approximate Weight (LB/100')

Inches

Millimeters

4

100

4.800

0.343

16

1020

317.5

6

150

6.900

0.493

16

440

658.7

8

200

9.050

0.646

20

200

1139.7

10

250

11.100

0.793

12

240

1722.3

12

300

13.200

0.943

28

60-80

2445.5

 

 

VINYLTECH AWWA C900-07
TECHNICAL DATA SUBMITTAL

CONFORMANCE
These specifications designate the requirements for manufacturing and installing Vinyltech AWWA C900 water pipe.

  • AWWA C900-07 - Polyvinyl Chloride (PVC) Pres­sure Pipe and Fabricated Fittings, 4 In. Through 12 In. (100mm Through 300mm), for Water Transmission and Distribution
  • AWWA C605 - Underground Installation of Poly­vi­nyl Chloride (PVC) Pressure Pipe and Fittings for Water
  • ASTM D1784 - Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
  • ASTM D3139 - Standard Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals
  • ASTM F477 - Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
  • ASTM D2412 - Standard Test Method for
    Determination of External Loading Characteristics of Plas­tic Pipe by Parallel-Plate Loading
  • UNI-PUB-8 - Tapping Guide for AWWA C900 Pressure Pipe
  • UNIB-8 - Recommended Practice for the Direct Tap­ping of PVC Pres­sure Water Pipe (Nominal Diameters 6-12 inch)

PIPE COMPOUND
The pipe shall be extruded from com­pounds meeting (PVC1120) the requirements of Cell Classification 12454-B, as defined in ASTM D 1784, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlo­ri­nat­ed Poly (Vinyl Chloride) (CPVC) Compounds. The PVC shall also be listed by the National Sanitation Foundation (NSF) for use in potable water.

PIPE
Vinyltech pipe shall be manufactured in
accordance with AWWA C900-07.

GASKET JOINT
The gasket shall be reinforced with a steel band and meet the requirements of ASTM F477. Vinyltech pipe shall have an integral bell end with a locked-in factory installed gasket and shall meet the joint requirements of ASTM D3139.

MARKING
The pipe shall be marked in accordance with
AWWA C900 as in the following example.

  1. Manufacturer’s name and production codes

  2. Nominal size, dimension ratio number, and O.D. base (for example, 8” DR 18 CIS)

  3. Materials cell classification (PVC1120)

  4. AWWA pressure class (235 psi or 305 psi) and hydrostatic test pressure (T600, or T800)

  5. AWWA designation number (AWWA C900-07)

  6. National Sanitaion Foundation (NSF-61)

  7. Production date and time code (VJHB10A 48:34)

  8. FM Approvals (FM) logo, third party certification

  9. Underwriters Laboratories, Inc (UL) logo, third party certification

QUALITY CONTROL
Each length of the pipe including the bell shall be hydrostatically tested in accordance with AWWA C900-97. The pipe shall meet all additional test requirements as described in AWWA C900. Our full time quality assurance staff continually administers a rigid program of tests
to maintain the production of the best pipe products available.

INSTALLATION
Recommended installation procedure of Vinyltech Corporation and the Uni-Bell PVC Pipe Association are outlined in AWWA C605, Underground Installation of Polyvinyl Chloride (PVC) Pressure Pipe and Fittings for Water. The Uni-
Bell Handbook of PVC Pipe is also an invaluable resource guide for design and installation.

TAPPING
The consistent success of tapping PVC pressure pipe is contingent upon the use of proper procedures and equipment. Vinyltech recommends strict compliance with the requirements as specified in UNI-B-8, UNI-PUB-8, and AWWA C605.

ASSEMBLING THE PIPE
Assembly of Vinyltech PVC transmission pipe is easily accomplished. A depth of entry mark is on each spigot end to serve as a visual check for rapid, accurate joint inspection. Do not over insert.

  1. Remove any mud, sand, or other foreign
    matter from the belled and spigot ends of the
    pipe. Carefully clean the gasket area.
  2. With a clean applicator (a brush or hand)
    lubricate the entire surface of the pipe from
    the spigot end to the depth of entry mark and
    the contact surface of the gasket with
    Vinyltech Brand Lubricant.
  3. Brace the bell to avoid disturbing the already
    installed joints. Align the pipe, insert the
    spigot into the bell and push until the entry
    mark is reached. Do not insert past the
    entry mark line.
201 South 61st Avenue • Phoenix, Arizona 85043 • Phone (602) 233-0071 • Fax (602) 272-4847
c