Nominal Size

Outer Diameter (Inches)

Minimum Wall (Inches)

14' Length Weight (Lb/100')

Approximate Weight
(LB/100')

Inches

Millimeters

4

100

4.215

0.120

105.7

104.2

6

150

6.275

0.180

232.6

229.0

8

200

8.400

0.240

417.8

410.3

10

250

10.500

0.300

657.4

643.9

12

300

12.500

0.360

944.1

922.7

15

375

15.300

0.437

1390.0

1361.0

 

Nominal Size

Outer Diameter (Inches)

Minimum Wall (Inches)

14' Length Weight
(LB/100')

 

Inches

Millimeters

4

100

4.215

0.162

150.0

6

150

6.275

0.241

320.0

8

200

8.400

0.323

580.0

10

250

10.500

0.404

900.0

12

300

12.500

0.481

1300.0

15

375

15.300

0.588

2000.0

 

 

Nominal Size

Outer Diameter (Inches)

Minimum Wall (Inches)

14' Length Weight
(LB/100')

20' Length Weight
(LB/100')

Inches

Millimeters

18

450

18.701

0.536

2115.0

2095.0
 

 

VINYLTECH SEWER PIPE
TECHNICAL DATA SUBMITTAL

CONFORMANCE
These specifications designate the requirements for manufacturing and installing Vinyltech PVC sewer pipe.

  • ASTM D 3034 - Standard Specification for Type
    PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and
    Fittings
  • ASTM F 679 - Standard Specification for Poly (Vinyl Chloride) (PVC) Large Diameter Plastic Gravity Sewer Pipe and fittings
  • ASTM D 3212 - Standard Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
  • ASTM F 477 - Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
  • ASTM D 1784 - Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and
    Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
  • ASTM D 2152 - Standard Test Method for Extruded Poly (Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion
  • ASTM D 2444 - Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of Tup (Falling Weight)
  • ASTM D 2321 - Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and other Gravity-Flow Applications
  • ASTM D 2412 - Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
  • IAPMO (File No. 2128) - Uniform Plumbing Code (UPC) - Vinyltech sewer pipe is IAPMO listed for ASTM 3034 SDR 35 4-15 inch and SDR 26 4-12 inch.

PIPE COMPOUND
The pipe shall be extruded from compounds meeting the requirements of Cell Classification 12454-B, as defined in ASTM D 1784, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds.

PIPE
Vinyltech and Northern Pipe Products pipe shall be manufactured in accordance with ASTM D 3034 (4"-15") and ASTM F 679 18"-24".

GASKET JOINT
The gasket shall be reinforced with a steel ring and meet the requirements of ASTM F477. Vinyltech pipe shall have an integral bell end with a locked-in factory installed gasket and shall meet the requirements of ASTM D 3212.

MARKING
The pipe shall be marked in accordance with ASTM D 3034 and F 679.

QUALITY CONTROL
Requirements for manufacturing and testing are conducted in strict accordance with ASTM specifications and are outlined in ASTM D 3034 and F 679.

INSTALLATION
Recommended installation procedure of Vinyltech Corporation and the Uni-Bell PVC Pipe Association are outlined in ASTM D 2321, Underground Installation of Flexible Thermoplastic Sewer Pipe. Vinyltech recommends the Uni-Bell Handbook of PVC Pipe as an invaluable resource guide.

ASSEMBLING THE PIPE
Assembling of Vinyltech PVC Sewer Pipe is easily accomplished by hand or by using a bar and block. A depth of entry mark is on each spigot end to serve as a visual check for rapid, accurate joint inspection. Do not over insert.

  1. Remove any mud, sand, or other foreign matter from the belled and spigot ends of the pipe. Carefully clean the gasket area.
  2. With a clean applicator (a brush or hand) lubricate the entire surface of the pipe from the spigot end to the depth of entry mark and the contact surface of the gasket with Vinyltech Brand Lubricant.
  3. Brace the bell to avoid disturbing the already installed joints. Align the pipe, insert the spigot into the bell and push until the entry mark is reached. Do not insert past the entry mark line.

 

 

201 South 61st Avenue • Phoenix, Arizona 85043 • Phone (602) 233-0071 • Fax (602) 272-4847